Lifting station Aqualift F Duo
Comfort, SPF 1500-S1
KESSEL Hebeanlage Aqualift F XL 200 l für Abwasserart fäkalienhaltig, mit 2 Pumpe/n SPF 1500, Freistromrad, Doppelanlage, für freie Aufstellung geeignet, Niveauerfassung über Tauchrohr mit Druckwächter, ohne Schieber
- Different performance classes available
- Pressure sensor for reliable pneumatic level measurement
- Control unit with self-diagnosis system
Item no. | 11604 |
---|---|
GTIN | 4026092071021 |
Price group | 20 |
Lifting station Aqualift F Duo Comfort, SPF 1500-S1
The lifting station for faecal and faecal-free wastewater is equipped with two submersible pumps and a backflow preventer. The collection tank made of permanently resistant polymer (PE) offers universal connection options and has a screwed access cover. The station is controlled by a user-friendly control unit, which can be optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface (Comfort control unit). Type of wastewater: wastewater with sewage Installation situation: free-standing set-up Version: Type of system: Twin pump station Shut-off valve: without shut-off valve Pump control: Control unit Backflow preventer: integrated Sound absorption mat: yes Delivery state: Installation-ready (electrical components, connection parts must be connected on site) General characteristics: Colour: black Standard: EN 12050-1 Dimensions: Length: 773 mm Width: 780 mm Height: 539 mm Tank: Number of inlets: 2 ST Inlet nominal size (DN): 100 Inlet nominal size (OD): 110 mm Inlet max. scoring (DN): 150 mm Distance pipe bottom inlet to tank bottom: 245 mm Distance from centre of inlet pipe to tank bottom: 300 mm Connection for manual diaphragm pump (DN): 32 Tank volume: 120 l Pumping volume: 50 l Pressure pipe connection: vertical Pressure pipe connection (DN): 100 mm Pressure pipe connection (OD): 110 mm Venting connection (DN): 70 mm Free passage: 40 mm Pumping device: Pump: SPF 1500 Number of pumps: 2 Max. pumping capacity: 40 m3/h Max. pumping height: 8 m Operating mode: S1 Power P1: 1.4 kW Power P2: 1.1 kW Speed: 1,415 U/min Max. temperature (permanent) of conveyed material: 40 °C Connection type: Direct connection Weight: 27 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 7G 1.5 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.77 Insulation class: F Control: Control unit: Comfort Operating voltage: 400 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes GSM interface: yes Potential-free contact: yes Type of fuse required (electrical protection): 3 x C 16 A Motor protection switch: yes Protection class control unit: IP 54 Length of mains cable for control unit: 0 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe with pressure monitor Alarm sensor: Immersion pipe
Installation Video
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Remote signal generator 20 m cable, 2x0.75 q | 20162 | Show | |
Retrofit kit Alarm float switch, Aqualift F and F Duo | 28015 | Show | |
Compressor set for air bubbling | 28048 | Show | |
Flexible coupling DN 80, L: 200 mm | 28662 | Show | |
Elastic union joint for hoses Ø 110 | 28663 | Show | |
Shut-off valve DN 80, Polymer, horizontal | 28682 | Show | |
Shut-off valve DN 100, Polymer, horizontal | 28683 | Show | |
Shut-off valve DN 100, Polymer | 28698 | Show | |
Shut-off valve DN 150, Polymer | 28699 | Show | |
Flange joint DN 100, for polymer fittings | 28712 | Show | |
Flange joint DN 80, for polymer fittings | 28713 | Show | |
Flange adapter DN 80, for polymer fitting | 28714 | Show | |
Shut-off valve DN 80, Polymer, vert | 28715 | Show | |
Shut-off valve DN 80, Polymer, vertical with flange | 28716 | Show | |
TeleControl GSM modem for Comfort control units 230V/400V | 28792 | Show |
Title | Item no. | ||
---|---|---|---|
Pressure switch Duo | 28046 | Show | |
Replacement set pump flange | 28051 | Show | |
Pump motor SPF 1500 / 400 V S1 | 28065 | Show | |
Gasket set fro pressure switch | 28608 | Show | |
Elastic union joint for hoses Ø 110 | 28663 | Show | |
Replacement set Duoflap housing | 28677 | Show | |
Comfort control unit 400V, Aqualift Duo, 2x2.5-4.0 A | 28757 | Show | |
Battery 9 V block | 680034 | Show | |
Cleaning cover screwed, 160x140 mm | 680044 | Show | |
Seal Pump flange | 680045 | Show | |
Attachment bracket with screws (2 ea.) | 680046 | Show | |
Screw set galvanised, 14 each | 680047 | Show | |
Immersion pipe pressure monitor, Duo, 10m,up to 12/2009 | 680049 | Show | |
Pump flange SPF 1400 - SPF 4500 | 680050 | Show | |
Seal for SPF 1400 - SPF 4500 | 680052 | Show | |
Flap set Rolling ring, flap, flap holder | 680053 | Show | |
Immersion pipe Duo, 5 m, from 01/2010 | 680056 | Show | |
Flap housing for Duo systems, without shut-off valve | 680061 | Show | |
Impeller SPF 1400/1500, Aqualift lifting stations | 680643 | Show |
Catalog Page | |
---|---|
Manuals | |
CAD Data | |
Test Reports and Certificates | |
Declaration of Performance | |
Declaration of Conformity |
- TÜV test mark (ATTR-376): ID 1111241940
- Country of origin (ATTR-322): DE
- Area of application (ATTR-264): drainage
- Pump type (ATTR-265): Freestanding pump
- Pump shaft position (ATTR-266): vertical
- Pump design (ATTR-267): Dry rotor pump
- Pump hydraulics (ATTR-268): single stage
- Pump suction characteristic (ATTR-269): non-self-priming
- Pump drive (ATTR-270): E-motor for three-phase current
- E-motor, type of startup (ATTR-271): direct
- Pump casing material (ATTR-272): Grey iron
- Upper tolerance of the operating voltage (+) (ATTR-273): 10 PROZ
- Lower tolerance of the operating voltage (-) (ATTR-274): 10 PROZ
- Upper tolerance of the nominal frequency (+) (ATTR-275): 3 PROZ
- Lower tolerance of the nominal frequency (-) (ATTR-276): 2 PROZ
- Pump electrical connection (ATTR-277): 3/N/PE 400V
- Startup circuit for three-phase connection or three-phase current (ATTR-278): Star
- Motor pump shaft (ATTR-279): continuous
- Shaft seal (ATTR-280): RSSR
- Number of operating pumps (ATTR-281): 1
- Minimum pumped media temperature (ATTR-282): 0 CEL
- Maximum operating pressure (Pmax) (ATTR-283): 800 HPA
- Minimum speed for speed adjustment (ATTR-284): no speed adjustment
- Start-up current (ATTR-285): 21 AMP
- Vertical installation (ATTR-286): yes
- Operating mode, twin systems (ATTR-287): redundant
- Pump (ATTR-4): SPF 1500
- Number of pumps (ATTR-181): 2
- Impeller type (ATTR-8): Multi-vane impeller
- Type of pump connection cable (ATTR-N2): H07RN-F 7G 1.5 mm2
- Max. permissible switching frequency (ATTR-162): 20 1PH
- Operating mode (ATTR-10): S1
- Power P1 (ATTR-F4): 1.4 KWT
- Power P2 (ATTR-F5): 1.1 KWT
- Speed (ATTR-F2): 1,415 UMIN
- Rated current (ATTR-N5): 2.7 AMP
- Max. pumping capacity (ATTR-F7): 40 MQH
- Max. pumping height (ATTR-F8): 8 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): Direct connection
- Protection class (pump) (ATTR-125): IP 68 (3m/48h)
- Length of mains cable for pump (ATTR-11): 5 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 27 KGM
- Cos phi - power factor (ATTR-192): 0.8
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 5,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 150,000
- Shut-off valve (ATTR-A1): without shut-off valve
- Pressure pipe connection (ATTR-B7): vertical
- Type of system (ATTR-2): Twin pump station
- Backflow preventer (ATTR-165): integrated
- Pump control (ATTR-134): Control unit
- Sound absorption mat (ATTR-185): yes
- Retaining bracket for the lift protection (ATTR-186): yes
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): yes
- Length of mains cable for control unit (ATTR-S12): 0 MTR
- Operating voltage (ATTR-S13): 400 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): Immersion pipe
- Type of level measurement (ATTR-7A): pneumatic
- Level measurement instrument (ATTR-7B): Immersion pipe with pressure monitor
- Type of fuse required (electrical protection) (ATTR-S17): 3 x C 16 A
- Motor protection switch (ATTR-172): yes
- Length (ATTR-A6A): 773 MMT
- Width (ATTR-A6B): 780 MMT
- Height (ATTR-A6C): 539 MMT
- Volume (ATTR-320): 0.3 MTQ
- Packaging dimension: length (ATTR-325): 773 MMT
- Packaging dimension: width (ATTR-326): 780 MMT
- Packaging dimension: height (ATTR-327): 539 MMT
- Dimensions (ATTR-323): 870X780X670MM
- Number of packages (ATTR-321): 1
- Number of inlets (ATTR-B1B): 2 PCE
- Inlet nominal size (DN) (ATTR-B1CA): 100 MMT
- Inlet nominal size (OD) (ATTR-B1CB): 110 MMT
- Distance from centre of inlet pipe to tank bottom (ATTR-B6): 300 MMT
- Distance pipe bottom inlet to tank bottom (ATTR-B1D): 245 MMT
- Inlet max. scoring (DN) (ATTR-B1E): 150 MMT
- Venting connection (DN) (ATTR-B4): 70 MMT
- Connection for manual diaphragm pump (DN) (ATTR-B4B): 32
- Pressure pipe connection (DN) (ATTR-B17): 100 MMT
- Pressure pipe connection (OD) (ATTR-B18): 110 MMT
- Tank volume (ATTR-B9): 120 LTR
- Pumping volume (ATTR-B10): 50 LTR
- Reaction to fire (ATTR-306): Class E to EN 13501-1
- Standard (ATTR-9): EN 12050-1
- CE marking (ATTR-A5B): yes
- Installation situation (ATTR-1): free-standing set-up
- Free passage (ATTR-180): 40 MMT
- Delivery state (ATTR-189): Installation-ready (electrical components, connection parts must be connected on site)
- Declaration of Performance (DOP) (ATTR-292): 009-011
- Wastewater quantity (ATTR-310): Medium
- Type of wastewater (ATTR-6): wastewater with sewage
- Declaration of conformity (ATTR-303): 009-011-D
- Colour (ATTR-102): black
- External monitoring (ATTR-A8): LGA
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Lifting stations
- Product type (M-ATTR-003): Lifting station
- Product family (M-ATTR-004): Aqualift
- Product name (M-ATTR-005): Aqualift F