Lifting station Aqualift S 200
Duo, GTF 600, Free-standing set-up
Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site. - With odour-tight cover and quick-release closure for easy maintenance - Tank made of PE, resistant to aggressive wastewater - Including backflow preventer for the pressure pipe - Including socket DN 100 and DN 150 for inlet and sampling - Integrated sampling possibility - Pumps with multi-vane impeller for maximum operating reliability - Including control unit for recording level and alarm detection
- 1. With odour-tight cover and quick-release closure for easy maintenance
- 2. Tank made of PE, resistant to aggressive wastewater
- 3. Including backflow preventer for the pressure pipe
Item no. | 28517 |
---|---|
GTIN | 4026092092934 |
Price group | 20 |
Lifting station Aqualift S 200 Duo, GTF 600, Free-standing set-up
Lifting station for faecal-free wastewater, free-standing set-up, preassembled for final installation on site. - With odour-tight cover and quick-release closure for easy maintenance - Tank made of PE, resistant to aggressive wastewater - Including backflow preventer for the pressure pipe - Including socket DN 100 and DN 150 for inlet and sampling - Integrated sampling possibility - Pumps with multi-vane impeller for maximum operating reliability - Including control unit for recording level and alarm detection Type of wastewater: wastewater without sewage Installation situation: free-standing set-up Version: Type of system: Twin pump station Pump control: Control unit Backflow preventer: integrated Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) General characteristics: Colour: black Standard: EN 12050-2 Dimensions: Length: 670 mm Width: 655 mm Height: 815 mm Tank: Inlet nominal size (DN): 100 Tank volume: 220 l Pumping volume: 100 l Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Coverage features: Type of cover: Cover Cover material: Polymer Colour of cover: violet Tightness: odour-tight Locking: Quick-release closure Free passage: 30 mm Pumping device: Pump: GTF 600 Number of pumps: 2 Max. pumping capacity: 12 m3/h Max. pumping height: 8 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 0.65 kW Power P2: 0.4 kW Speed: 2,750 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 6 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.9 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Insulation class: F Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Motor protection switch: yes Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Alarm sensor: Immersion pipe
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Remote signal generator 20 m cable, 2x0.75 q | 20162 | Show | |
Retrofit kit Alarm float switch | 28016 | Show | |
Hole saw for DN 100/125/150 | 500100 | Show | |
Hole saw for DN 50/70/100 | 500101 | Show | |
Potential-free contact Additional circuit board for control units. | 80072 | Show | |
10 m probe cable extension set | 80889 | Show | |
Cable prolongation set for pump 10 m | 80891 | Show | |
Seal for pipe penetration, DN 50 | 850114 | Show | |
Seal for channel passage 75 mm | 850116 | Show | |
Seal for channel passage 110 mm | 850117 | Show | |
Seal for pipe penetration, DN 125 | 850118 | Show | |
Seal for pipe penetration, DN 150 | 850119 | Show |
Title | Item no. | ||
---|---|---|---|
Control unit Aqualift Comfort 230 V Duo | 28746 | Show | |
One-handed closure for backflow preventer | 680018 | Show | |
Battery 9 V block | 680034 | Show | |
Seal for pressure pipe connection | 680067 | Show | |
Cover with seal | 680076 | Show | |
Seal for upper section, from 07/2014 | 680150 | Show | |
Cover d: 420 mm, up to 03/2004 | 680326 | Show | |
Pump connection with seal and flap | 680475 | Show | |
Pump connection Minilift, Aqualift S | 680760 | Show | |
Turn fastener for pump connection lock | 680762 | Show | |
Flap housing Duo, with pump connector | 680781 | Show | |
Impeller GTF 600, free passage 30 mm | 680887 | Show | |
Spiral housing GTF 600, free passage 30 mm | 680888 | Show | |
Bracket for pressure pipe, Duo | 680972 | Show | |
Pump hanger GTF 600, Duo | 680973 | Show | |
Clamp fastener for cover 450 mm | 680975 | Show | |
Replacement pump GTF 600 without float switch, 5 m | 680977 | Show | |
Dummy cover for Aqualift S 100/200 lifting station | 680980 | Show | |
Cable gland for Aqualift S 100/200 | 680981 | Show | |
Connection adapter for Aqualift S 100/200 locking device | 680985 | Show | |
Inlet socket DN 100 for Aqualift S 100/200 | 680986 | Show | |
Inlet socket DN 150 for Aqualift S 100/200 | 680987 | Show | |
Immersion pipe for Aqualift S 200 lifting station | 680989 | Show | |
Sound absorption mat for Aqualift S 200 lifting station | 680991 | Show | |
Pressure pipe DN 32 for Aqualift S 200 GTF 600 | 680992 | Show | |
Venting socket DN 70 for Aqualift S 200 | 680994 | Show | |
Connector for Aqualift S 200 immersion pipe | 680995 | Show | |
Hose connection set for immersion pipes, Length 5 m | 680996 | Show |
Catalog Page | |
---|---|
Manuals | |
CAD Data | |
Test Reports and Certificates | |
Declaration of Performance | |
Declaration of Conformity |
- Wastewater quantity (ATTR-310): Medium
- Type of wastewater (ATTR-6): wastewater without sewage
- Free passage (ATTR-180): 30 MMT
- TÜV test mark (ATTR-376): ID 1111241937
- Country of origin (ATTR-322): DE
- Area of application (ATTR-264): drainage
- Pump type (ATTR-265): submersible pump
- Pump shaft position (ATTR-266): vertical
- Pump design (ATTR-267): Dry rotor pump
- Pump hydraulics (ATTR-268): single stage
- Pump suction characteristic (ATTR-269): non-self-priming
- Pump drive (ATTR-270): E-motor for alternating current
- Pump casing material (ATTR-272): Polymer
- Upper tolerance of the operating voltage (+) (ATTR-273): 10 PROZ
- Lower tolerance of the operating voltage (-) (ATTR-274): 10 PROZ
- Upper tolerance of the nominal frequency (+) (ATTR-275): 3 PROZ
- Lower tolerance of the nominal frequency (-) (ATTR-276): 2 PROZ
- Pump electrical connection (ATTR-277): 1/N/PE 230V
- Startup circuit for three-phase connection or three-phase current (ATTR-278):
- Motor pump shaft (ATTR-279): continuous
- Shaft seal (ATTR-280): RSSR
- Number of operating pumps (ATTR-281): 1
- Minimum pumped media temperature (ATTR-282): 0 CEL
- Maximum operating pressure (Pmax) (ATTR-283): 800 HPA
- Minimum speed for speed adjustment (ATTR-284): no speed adjustment
- Vertical installation (ATTR-286): yes
- Pump (ATTR-4): GTF 600
- Number of pumps (ATTR-181): 2
- Impeller type (ATTR-8): Multi-vane impeller
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Operating mode (ATTR-10): S1
- Power P1 (ATTR-F4): 0.7 KWT
- Power P2 (ATTR-F5): 0.4 KWT
- Speed (ATTR-F2): 2,750 UMIN
- Operating voltage (ATTR-131): 230 VLT
- Mains frequency (ATTR-N4): 50 HTZ
- Rated current (ATTR-N5): 2.9 AMP
- Max. pumping capacity (ATTR-F7): 12 MQH
- Max. pumping height (ATTR-F8): 8 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): coded plug
- Protection class (pump) (ATTR-125): IP 68 (3m)
- Length of mains cable for pump (ATTR-11): 5 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 6 KGM
- Insulation class (ATTR-193): F
- Type of system (ATTR-2): Twin pump station
- Backflow preventer (ATTR-165): integrated
- Pump control (ATTR-134): Control unit
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): Immersion pipe
- Type of level measurement (ATTR-7A): pneumatic
- Motor protection switch (ATTR-172): yes
- - (ATTR-S21):
- - (ATTR-S22):
- - (ATTR-S23):
- Inlet nominal size (DN) (ATTR-B1CA): 100 MMT
- Pressure pipe connection (DN) (ATTR-B17): 50 MMT
- Pressure pipe connection (OD) (ATTR-B18): 63 MMT
- Tank volume (ATTR-B9): 220 LTR
- Pumping volume (ATTR-B10): 100 LTR
- Type of cover (ATTR-A21): Cover
- Colour of cover (ATTR-A2A): violet
- Tightness (ATTR-A2C): odour-tight
- Locking (ATTR-A2D): Quick-release closure
- Cover material (ATTR-A2E): Polymer
- Length (ATTR-A6A): 670 MMT
- Width (ATTR-A6B): 655 MMT
- Height (ATTR-A6C): 815 MMT
- Volume (ATTR-320): 0.8 MTQ
- Packaging dimension: length (ATTR-325): 900 MMT
- Packaging dimension: width (ATTR-326): 900 MMT
- Packaging dimension: height (ATTR-327): 939 MMT
- Dimensions (ATTR-323): 900X900X939MM
- Number of packages (ATTR-321): 1
- Installation situation (ATTR-1): free-standing set-up
- Declaration of Performance (DOP) (ATTR-292): 009-210
- Declaration of conformity (ATTR-303): 009-210-D
- Colour (ATTR-102): black
- Standard (ATTR-9): EN 12050-2
- CE marking (ATTR-A5B): yes
- Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Lifting stations
- Product type (M-ATTR-003): Lifting station
- Product family (M-ATTR-004): Aqualift
- Product name (M-ATTR-005): Aqualift S
- - (ATTR-370):