The lifting station for faecal and faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an enclosed pump tank. One-handed closures enable easy removal of the integrated components. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages that can be output via a GSM interface.

  • Suitable for complete basement drainage
  • Integrated drainage function when installed in the floor slab
  • Maximum operating reliability due to intelligent control unit (Duo)
Item no. 28717
GTIN 4026092093405
Price group 20

    Lifting station Aqualift F Compact Mono, SPZ 1000-S3, Free-standing set-up
    The lifting station for faecal and faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an enclosed pump tank. One-handed closures enable easy removal of the integrated components. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages that can be output via a GSM interface. Type of wastewater: wastewater with sewage Installation situation: free-standing set-up Version: Type of system: Single station Shut-off valve: without shut-off valve Pump control: Control unit Backflow preventer: integrated Sound absorption mat: yes Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) General characteristics: Colour: black Approval: Z-53.2-484 Dimensions: Length: 670 mm Width: 580 mm Height: 395 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 100 Inlet nominal size (OD): 110 mm Distance pipe bottom inlet to tank bottom: 152 mm Distance from centre of outlet pipe to tank bottom: 350 mm Distance from centre of inlet pipe to tank bottom: 207 mm Tank volume: 40 l Pumping volume: 20 l Pressure pipe connection: horizontal Pressure pipe connection (DN): 32 mm Pressure pipe connection (OD): 40 mm Venting connection (DN): 70 mm Coverage features: Type of cover: - Pumping device: Pump: SPZ 1000 Number of pumps: 1 Max. pumping capacity: 11.5 m3/h Max. pumping height: 10 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S3 - 50 % Power P1: 1.2 kW Power P2: 0.69 kW Speed: 2,800 U/min Type of fuse required (electrical protection): Fuse protection through control unit 230 V Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Macerator Length of mains cable for pump: 5 m Rated current: 5.2 A Protection class (pump): IP 68 Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.97 Insulation class: F Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Type of fuse required (electrical protection): C 16 A Motor protection switch: yes Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe Alarm sensor: optical probe

    Installation Video

      Title Item no.  
      Title Item no.  
      Title Item no.  
    Adapter DN 50/70 27126 Show
    Adapter DN 100/70 27602 Show
    Pressure pipe set 5 m pressure hose, DA 40 mm 28040 Show
    Pressure pipe set with 5 m pressure hose, DA 50 mm 28062 Show
    Adapter for pressure connection PE DA40 28086 Show
    Odour trap Multistop, System 125 48500 Show
    Odour trap Megastop 48550 Show
    Hair filter Polymer, for System 125 bathroom drains 48700 Show
    Odour trap for The Ultraflat 79 680696 Show
    Drain body for cover plate for odour trap 50 mm, black 680795 Show
    Drain body for cover plate for Multistop, black 680796 Show
    Drain body for cover plate for odour trap 50 mm, grey 680797 Show
    Drain body for cover plate for Multistop, grey 680798 Show
    Cover plate water tight, black 83050 Show
    Cover plate water tight 83052 Show
    Extension section H: 200 mm 83070 Show
    Extension section H: 234 mm, with flange and counter-flange 83073 Show
    Extension section H: 360 mm, with central flange 83075 Show
    Waterproof concrete install. kit OD: 40 mm, for building contractors 83077 Show
      Title Item no.  
    KTP1000 cutting assembly replacement set 28075 Show
    Splash guard set for optical probe 28706 Show
    Control Unit Aqualift Comfort 230 V Mono 28731 Show
    Cover Pump Opening KTP 1000 28732 Show
    KESSEL Pump plate 28733 Show
    Set connection piece submersible pipe 28734 Show
    Replacement pump for Aqualift F Compact 28739 Show
    Submersible pipe with horizontal outlet 28744 Show
    One-handed closure for backflow preventer 680018 Show
    Battery 9 V block 680034 Show
    Pump connection for pumping stations, up to 12/2015 680065 Show
    Turn fastener for pumps 680070 Show
    Cover with seal 680076 Show
    Bracket Pressure pipe connection 680119 Show
    Seal set Aqualift F Compact Mono 680453 Show
    Replacement set optical probe 80888 Show
    Adapter set optical probe 80892 Show
    • Installation situation (ATTR-1): free-standing set-up
    • Country of origin (ATTR-322): DE
    • - (ATTR-370):
    • Area of application (ATTR-264): drainage
    • Pump type (ATTR-265): Freestanding pump
    • Pump shaft position (ATTR-266): vertical
    • Pump design (ATTR-267): Dry rotor pump
    • Pump hydraulics (ATTR-268): single stage
    • Pump suction characteristic (ATTR-269): non-self-priming
    • Pump drive (ATTR-270): E-motor for alternating current
    • E-motor, type of startup (ATTR-271): direct
    • Pump casing material (ATTR-272): Polymer
    • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
    • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
    • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
    • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
    • Pump electrical connection (ATTR-277): 1/N/PE 230V
    • Startup circuit for three-phase connection or three-phase current (ATTR-278):
    • Motor pump shaft (ATTR-279): continuous
    • Shaft seal (ATTR-280): RSSR
    • Number of operating pumps (ATTR-281): 1
    • Minimum pumped media temperature (ATTR-282): 0  CEL
    • Maximum operating pressure (Pmax) (ATTR-283): 1,000  HPA
    • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
    • Vertical installation (ATTR-286): yes
    • Pump (ATTR-4): SPZ 1000
    • Number of pumps (ATTR-181): 1
    • Impeller type (ATTR-8): Macerator
    • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
    • Type of fuse required (electrical protection) (ATTR-N3): Fuse protection through control unit 230 V
    • Max. permissible switching frequency (ATTR-162): 20  1PH
    • Operating mode (ATTR-10): S3 - 50 %
    • Power P1 (ATTR-F4): 1.2  KWT
    • Power P2 (ATTR-F5): 0.7  KWT
    • Speed (ATTR-F2): 2,800  UMIN
    • Operating voltage (ATTR-131): 230  VLT
    • Mains frequency (ATTR-N4): 50  HTZ
    • Rated current (ATTR-N5): 5.2  AMP
    • Max. pumping capacity (ATTR-F7): 11.5  MQH
    • Max. pumping height (ATTR-F8): 10  MTR
    • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): coded plug
    • Protection class (pump) (ATTR-125): IP 68
    • Length of mains cable for pump (ATTR-11): 5  MTR
    • Temperature monitoring (ATTR-135): integrated
    • Weight (ATTR-191): 10  KGM
    • Cos phi - power factor (ATTR-192): 1.0
    • Insulation class (ATTR-193): F
    • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
    • Expected service life (number of switching cycles) (ATTR-195): 150,000
    • Length (ATTR-A6A): 670  MMT
    • Width (ATTR-A6B): 580  MMT
    • Height (ATTR-A6C): 395  MMT
    • Volume (ATTR-320): 0.2  MTQ
    • Packaging dimension: length (ATTR-325): 620  MMT
    • Packaging dimension: width (ATTR-326): 620  MMT
    • Packaging dimension: height (ATTR-327): 515  MMT
    • Dimensions (ATTR-323): 620X620X515MM
    • Number of packages (ATTR-321): 1
    • Shut-off valve (ATTR-A1): without shut-off valve
    • Pressure pipe connection (ATTR-B7): horizontal
    • Type of system (ATTR-2): Single station
    • Backflow preventer (ATTR-165): integrated
    • Pump control (ATTR-134): Control unit
    • Sound absorption mat (ATTR-185): yes
    • Retaining bracket for the lift protection (ATTR-186): yes
    • Control unit (ATTR-S2): Comfort
    • Self-diagnosis system (SDS) (ATTR-S5): yes
    • Battery buffering (ATTR-S6): yes
    • Multi-line display (ATTR-S7): yes
    • Log book function (ATTR-S8): yes
    • USB interface (ATTR-S9): yes
    • GSM interface (ATTR-S10): yes
    • Potential-free contact (ATTR-S11): optional
    • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
    • Operating voltage (ATTR-S13): 230  VLT
    • Mains frequency (ATTR-S14): 50  HTZ
    • Protection class control unit (ATTR-S4): IP 54
    • Alarm sensor (ATTR-S1): optical probe
    • Type of level measurement (ATTR-7A): pneumatic
    • Level measurement instrument (ATTR-7B): Immersion pipe
    • Type of fuse required (electrical protection) (ATTR-S17): C 16 A
    • Motor protection switch (ATTR-172): yes
    • - (ATTR-S21):
    • - (ATTR-S22):
    • - (ATTR-S23):
    • Number of inlets (ATTR-B1B): 1  PCE
    • Inlet nominal size (DN) (ATTR-B1CA): 100  MMT
    • Inlet nominal size (OD) (ATTR-B1CB): 110  MMT
    • Distance from centre of inlet pipe to tank bottom (ATTR-B6): 207  MMT
    • Distance pipe bottom inlet to tank bottom (ATTR-B1D): 152  MMT
    • Distance from centre of outlet pipe to tank bottom (ATTR-B15E): 350  MMT
    • Venting connection (DN) (ATTR-B4): 70  MMT
    • Pressure pipe connection (DN) (ATTR-B17): 32  MMT
    • Pressure pipe connection (OD) (ATTR-B18): 40  MMT
    • Tank volume (ATTR-B9): 40  LTR
    • Pumping volume (ATTR-B10): 20  LTR
    • Type of cover (ATTR-A21): -
    • Approval (ATTR-A5): Z-53.2-484
    • Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
    • Declaration of Performance (DOP) (ATTR-292): 009-064
    • Wastewater quantity (ATTR-310): Medium
    • Type of wastewater (ATTR-6): wastewater with sewage
    • Declaration of conformity (ATTR-303): 009-064-D
    • Colour (ATTR-102): black
    • Brand (M-ATTR-001): KESSEL
    • Product group (M-ATTR-002): Lifting stations
    • Product type (M-ATTR-003): Lifting station
    • Product family (M-ATTR-004): Aqualift
    • Product name (M-ATTR-005): Aqualift F Compact
    • Start-up current (ATTR-285): 14.9  AMP