Skip to main content

Pumping station Aquapump Medium

Mono, GTF1200, 1300-1750 mm, B

The pumping station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank is an LW 600 chamber system made of permanently resistant polymer (PE-LLD) with open pump tank and universal connection options. Quick-release closures enable the integrated components to be removed easily. The station is optionally controlled by a user-friendly control unit, which can be integrated in the building management system via a potential-free contact. Alternatively, alarm and collective fault messages can be output via a GSM interface.

  • Maximum safety
  • Flexible installation
  • LW 600 chamber system suitable for underground installation
Item no. 827820B
GTIN 4026092045732
Price group 60

Pumping station Aquapump Medium Mono, GTF1200, 1300-1750 mm, B
The pumping station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank is an LW 600 chamber system made of permanently resistant polymer (PE-LLD) with open pump tank and universal connection options. Quick-release closures enable the integrated components to be removed easily. The station is optionally controlled by a user-friendly control unit, which can be integrated in the building management system via a potential-free contact. Alternatively, alarm and collective fault messages can be output via a GSM interface. Type of wastewater: wastewater without sewage Installation situation: underground installation Version: Type of system: Single station Installation: Wet installation Pump control: Float switch Backflow preventer: integrated Passage seal for ventilation pipe (DN): 100 mm Passage seal for conduit pipe (DN): 100 mm Delivery state: Modular set for assembly on site General characteristics: Colour: grey Standard: EN 12050-2 Dimensions: Length: 806 mm Width: 806 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 150 Inlet nominal size (OD): 160 mm Distance pipe bottom inlet to tank bottom: 400 mm Distance from centre of outlet pipe to tank bottom: 894 mm Distance from centre of inlet pipe to tank bottom: 455 mm Connection conduit pipe (DN): 100 mm Pressure pipe connection: horizontal Pressure pipe connection (DN): 32 mm Pressure pipe connection (OD): 40 mm Installation depth: 1,300 - 1,750 mm Venting connection (DN): 100 mm Groundwater resistant from lower edge of base section: 2,000 mm Clear width of tank (LW): 600 mm Clear width of entry (LW): 600 mm Chamber system: LW 600 Vertical adjustment: vertically adjustable upper section Coverage features: Type of cover: Round cover plate Cover material: Grey iron Colour of cover: black Load class: B 125 (EN 124) Length: 648 mm Width: 648 mm Height: 103 mm Locking: unlocked Pumping device: Pump: GTF 1200 Number of pumps: 1 Max. pumping capacity: 15.5 m3/h Max. pumping height: 9 m Operating mode: S3 - 50 % Power P1: 1.4 kW Power P2: 0.84 kW Speed: 2,650 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Schuko (earthed contact) 2-pin Weight: 10 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 6.2 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.98 Insulation class: F Control: Operating voltage: 230 V Mains frequency: 50 Hz Type of level measurement: mechanical Level measurement instrument: Float switch
  Title Item no.  
  Title Item no.  
  Title Item no.  
Basic warning device with electronic probe 20222 Show
Basic warning device with optical probe 20223 Show
Compressor set for air bubbling 28048 Show
TeleControl GSM modem for Comfort control units 230V/400V 28792 Show
Connection box for level sensor extension 28799 Show
Replacement set optical probe 80888 Show
10 m probe cable extension set 80889 Show
Cable prolongation set for pump 10 m 80891 Show
Installation set Thermostat, Hygrostat 97713 Show
Outdoor control cabinet W: 590 mm, for control unit installation 97714 Show
Warning beacon for outdoor control cabinet 97715 Show
Outdoor control cabinet W: 460 mm, for control unit installation 97716 Show
Outdoor control cabinet W: 785 mm, for control unit installation 97723 Show
Outdoor control cabinet W: 1115 mm, for control unit installation 97724 Show
  Title Item no.  
One-handed closure for backflow preventer 680018 Show
Seal for pressure pipe connection 680067 Show
Clamping ring for upper sections d: 600 mm 680276 Show
Pump stand for pumping stations 680362 Show
Spiral housing for passage 30 mm 680363 Show
Impeller for passage 30 mm 680366 Show
Riser 1300 - 1750 mm 680450 Show
Backflow preventer with non-return flap 680457 Show
Pump connection for pumping stations, from 01/2016 680476 Show
Pump connection Mono, suitable for pumping stations 680479 Show
Seal set Non-return flap, seals 680490 Show
Replacement pump Aquadive GTF1200 with float switch, 10 m 680594 Show
One-handed closure for threaded connection 680698 Show
Sensor clamp for level sensor & subm. press. switch 680729 Show
Seal for channel passage 110 mm 850117 Show
Seal for upper section 860116 Show
Cover plate,cast iron class B not bolted 860131 Show
  • TÜV test mark (ATTR-376): ID 1111241937
  • Country of origin (ATTR-322): DE
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): submersible pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for alternating current
  • E-motor, type of startup (ATTR-271): direct
  • Pump casing material (ATTR-272): Polymer
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 1/N/PE 230V
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 900  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 14.9  AMP
  • Vertical installation (ATTR-286): yes
  • Pump (ATTR-4): GTF 1200
  • Number of pumps (ATTR-181): 1
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
  • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
  • Max. permissible switching frequency (ATTR-162): 20  1PH
  • Operating mode (ATTR-10): S3 - 50 %
  • Power P1 (ATTR-F4): 1.4  KWT
  • Power P2 (ATTR-F5): 0.8  KWT
  • Speed (ATTR-F2): 2,650  UMIN
  • Rated current (ATTR-N5): 6.2  AMP
  • Max. pumping capacity (ATTR-F7): 15.5  MQH
  • Max. pumping height (ATTR-F8): 9  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): Schuko (earthed contact) 2-pin
  • Protection class (pump) (ATTR-125): IP 68 (3m)
  • Length of mains cable for pump (ATTR-11): 10  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Weight (ATTR-191): 10  KGM
  • Cos phi - power factor (ATTR-192): 1.0
  • Insulation class (ATTR-193): F
  • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
  • Expected service life (number of switching cycles) (ATTR-195): 150,000
  • Net weight (ATTR-A3A): 121  KGM
  • Gross weight (ATTR-A3B): 128  KGM
  • Installation depth (ATTR-B2_VB): 1,300  MMT
  • Length (ATTR-A6A): 806  MMT
  • Width (ATTR-A6B): 806  MMT
  • Volume (ATTR-320): 1.7  MTQ
  • Packaging dimension: length (ATTR-325): 1,200  MMT
  • Packaging dimension: width (ATTR-326): 800  MMT
  • Packaging dimension: height (ATTR-327): 1,720  MMT
  • Dimensions (ATTR-323): 900X900X1900MM
  • Number of packages (ATTR-321): 1
  • Pressure pipe connection (ATTR-B7): horizontal
  • Chamber system (ATTR-B8): LW 600
  • Type of system (ATTR-2): Single station
  • Installation (ATTR-164): Wet installation
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Float switch
  • Passage seal for ventilation pipe (DN) (ATTR-183): 100  MMT
  • Passage seal for conduit pipe (DN) (ATTR-184): 100  MMT
  • Operating voltage (ATTR-S13): 230  VLT
  • Mains frequency (ATTR-S14): 50  HTZ
  • Type of level measurement (ATTR-7A): mechanical
  • Level measurement instrument (ATTR-7B): Float switch
  • Type of cover (ATTR-A21): Round cover plate
  • Colour of cover (ATTR-A2A): black
  • Load class (ATTR-A2B): B 125 (EN 124)
  • Locking (ATTR-A2D): unlocked
  • Cover material (ATTR-A2E): Grey iron
  • Length (ATTR-A2M): 648  MMT
  • Width (ATTR-A2N): 648  MMT
  • Height (ATTR-A2P): 103  MMT
  • Clear width of entry (LW) (ATTR-B13): 600  MMT
  • Clear width of tank (LW) (ATTR-B14): 600  MMT
  • Number of inlets (ATTR-B1B): 1  PCE
  • Inlet nominal size (DN) (ATTR-B1CA): 150
  • Inlet nominal size (OD) (ATTR-B1CB): 160  MMT
  • Distance from centre of inlet pipe to tank bottom (ATTR-B6): 455  MMT
  • Distance pipe bottom inlet to tank bottom (ATTR-B1D): 400  MMT
  • Distance from centre of outlet pipe to tank bottom (ATTR-B15E): 894  MMT
  • Connection conduit pipe (DN) (ATTR-B3): 100  MMT
  • Venting connection (DN) (ATTR-B4): 100  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 32  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 40  MMT
  • Groundwater resistant from lower edge of base section (ATTR-B12): 2,000  MMT
  • Vertical adjustment (ATTR-177): vertically adjustable upper section
  • Declaration of Performance (DOP) (ATTR-292): 009-072
  • Installation situation (ATTR-1): underground installation
  • Wastewater quantity (ATTR-310): Medium
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Colour (ATTR-102): grey
  • Standard (ATTR-9): EN 12050-2
  • CE marking (ATTR-A5B): yes
  • Delivery state (ATTR-189): Modular set for assembly on site
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Pumping station
  • Product family (M-ATTR-004): Aqualift
  • Product name (M-ATTR-005): Aqualift S