Skip to main content

Pumping station Aquapump Small

Mono, Basic, STF 1300-S3

The pumping station for faecal wastewater is suitable for underground installations and is equipped with a backflow preventer for the pressure pipe. The PE tank is resistant to domestic wastewater and includes a pedestrian class polymer cover plate. The pump with multi-vane impeller ensures maximum operating reliability. Quick-release closures enable the integrated components to be removed easily. The components are pre-assembled for final assembly on site. Including openings for inlet, ventilation and cable duct.

  • Variable connection options
  • With quick-release closures for easy removal and cleaning
  • Vertically adjustable upper section
Item no. 829710
GTIN 4026092083598
Price group 20

    Pumping station Aquapump Small Mono, Basic, STF 1300-S3
    The pumping station for faecal wastewater is suitable for underground installations and is equipped with a backflow preventer for the pressure pipe. The PE tank is resistant to domestic wastewater and includes a pedestrian class polymer cover plate. The pump with multi-vane impeller ensures maximum operating reliability. Quick-release closures enable the integrated components to be removed easily. The components are pre-assembled for final assembly on site. Including openings for inlet, ventilation and cable duct. Type of wastewater: wastewater with sewage Installation situation: underground installation Version: Type of system: Single station Installation: Dry installation Pump control: Float switch Backflow preventer: integrated General characteristics: Colour: black Standard: EN 12050-1 Dimensions: Length: 615 mm Width: 600 mm Height: 830 mm Tank: Inlet max. scoring (DN): 100 mm Pumping volume: 25 l Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Coverage features: Type of cover: Round cover plate Colour of cover: black Load class: K 3 (EN 1253-1) Locking: locked Free passage: 40 mm Pumping device: Pump: STF 1300 Number of pumps: 2 Max. pumping capacity: 21 m3/h Max. pumping height: 10 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S3 - 50 % Power P1: 1.3 kW Power P2: 0.8 kW Speed: 2,650 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 6 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Insulation class: F Control: Motor protection switch: yes Level measurement instrument: Float switch
      Title Item no.  
      Title Item no.  
      Title Item no.  
      Title Item no.  
    Seal for upper section, from 07/2014 680150 Show
    One-handed closure DN 63 680380 Show
    Backflow preventer right, with non-return flap 680382 Show
    Non-return flap for Pumpfix XL 680630 Show
    Cover plate round, incl. screws and seal 680801 Show
    Flap housing with pressure piping, DA: 50 mm 680802 Show
    Replacement pump STF 1300 230 V, with float switch 680803 Show
    Multi-vane impeller for STF 1300 680804 Show
    Spiral housing for STF 1300 680805 Show
    Pressure pipe connection for pumping stations Mono 680807 Show
    • Country of origin (ATTR-322): DE
    • Area of application (ATTR-264): drainage
    • Pump type (ATTR-265): Freestanding pump
    • Pump shaft position (ATTR-266): vertical
    • Pump design (ATTR-267): Dry rotor pump
    • Pump hydraulics (ATTR-268): single stage
    • Pump suction characteristic (ATTR-269): non-self-priming
    • Pump drive (ATTR-270): E-motor for alternating current
    • E-motor, type of startup (ATTR-271): direct
    • Pump casing material (ATTR-272): Polymer
    • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
    • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
    • Pump electrical connection (ATTR-277): 1/N/PE 230V
    • Startup circuit for three-phase connection or three-phase current (ATTR-278):
    • Motor pump shaft (ATTR-279): continuous
    • Shaft seal (ATTR-280): RSSR
    • Number of operating pumps (ATTR-281): 1
    • Minimum pumped media temperature (ATTR-282): 0  CEL
    • Maximum operating pressure (Pmax) (ATTR-283): 1,000  HPA
    • Start-up current (ATTR-285): 14.9  AMP
    • Vertical installation (ATTR-286): yes
    • Pump (ATTR-4): STF 1300
    • Number of pumps (ATTR-181): 2
    • Impeller type (ATTR-8): Multi-vane impeller
    • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
    • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
    • Operating mode (ATTR-10): S3 - 50 %
    • Power P1 (ATTR-F4): 1.3  KWT
    • Power P2 (ATTR-F5): 0.8  KWT
    • Speed (ATTR-F2): 2,650  UMIN
    • Operating voltage (ATTR-131): 230  VLT
    • Mains frequency (ATTR-N4): 50  HTZ
    • Rated current (ATTR-N5): 6  AMP
    • Max. pumping capacity (ATTR-F7): 21  MQH
    • Max. pumping height (ATTR-F8): 10  MTR
    • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): coded plug
    • Protection class (pump) (ATTR-125): IP 68 (3m)
    • Length of mains cable for pump (ATTR-11): 10  MTR
    • Temperature monitoring (ATTR-135): integrated
    • Weight (ATTR-191): 10  KGM
    • Insulation class (ATTR-193): F
    • Free passage (ATTR-180): 40  MMT
    • Net weight (ATTR-A3A): 26  KGM
    • Type of cover (ATTR-A21): Round cover plate
    • Colour of cover (ATTR-A2A): black
    • Load class (ATTR-A2B): K 3 (EN 1253-1)
    • Locking (ATTR-A2D): locked
    • Length (ATTR-A6A): 615  MMT
    • Width (ATTR-A6B): 600  MMT
    • Height (ATTR-A6C): 830  MMT
    • Volume (ATTR-320): 0.5  MTQ
    • Packaging dimension: length (ATTR-325): 792  MMT
    • Packaging dimension: width (ATTR-326): 653.8  MMT
    • Packaging dimension: height (ATTR-327): 916.3  MMT
    • Dimensions (ATTR-323): 80X70X95 CM
    • Number of packages (ATTR-321): 0
    • Type of system (ATTR-2): Single station
    • Installation (ATTR-164): Dry installation
    • Backflow preventer (ATTR-165): integrated
    • Pump control (ATTR-134): Float switch
    • Inlet max. scoring (DN) (ATTR-B1E): 100  MMT
    • Pressure pipe connection (DN) (ATTR-B17): 50  MMT
    • Pressure pipe connection (OD) (ATTR-B18): 63  MMT
    • Pumping volume (ATTR-B10): 25  LTR
    • Gross weight (ATTR-A3B): 32  KGM
    • Motor protection switch (ATTR-172): yes
    • Colour (ATTR-102): black
    • Standard (ATTR-9): EN 12050-1
    • Declaration of Performance (DOP) (ATTR-292): 009-086
    • Type of wastewater (ATTR-6): wastewater with sewage
    • Installation situation (ATTR-1): underground installation
    • Brand (M-ATTR-001): KESSEL
    • Product group (M-ATTR-002): Lifting stations
    • Product type (M-ATTR-003): Pumping station
    • Product family (M-ATTR-004): Aqualift
    • Product name (M-ATTR-005): Aqualift F Basic
    • - (ATTR-370):
    • Level measurement instrument (ATTR-7B): Float switch