Staufix FKA automatic backwater valve
DN 100, Floor slab, tileable
The Premium automatic backwater valve for faecal and faecal-free wastewater is equipped with a motor-driven closure system which is closed automatically in the event of backwater. A second closure system serves as an emergency closure to be closed by hand. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. Thanks to the modular KESSEL system, existing systems can easily be converted to a Pumpfix F backwater pumping station.
- Safe, motor-driven closure system with optical probe
- Fast, simple and toolless maintenance
- Available as a complete set or module set
Item no. | 84100X |
---|---|
GTIN | 4026092046449 |
Price group | 30 |
Staufix FKA automatic backwater valve DN 100, Floor slab, tileable
The Premium automatic backwater valve for faecal and faecal-free wastewater is equipped with a motor-driven closure system which is closed automatically in the event of backwater. A second closure system serves as an emergency closure to be closed by hand. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. Thanks to the modular KESSEL system, existing systems can easily be converted to a Pumpfix F backwater pumping station. Type of wastewater: wastewater with sewage Installation situation: floor slab installation Version: Type of waterproofing layer: Waterproofing layer Emergency closure: yes Delivery state: Pre-mounted for final assembly on site (sensor system must be fitted on site and control unit must be connected) Backwater protection: Type 3 Number of mechanical backwater flaps: 1 Number of motor-driven backwater flaps: 1 General characteristics: Nominal size (DN): 100 Outer diameter (OD): 110 Colour: black Standard: EN 13564 Dimensions: Length: 642 mm Width: 590 mm Cutout dimension, length: 750 mm Cutout dimension, width: 750 mm Tank: Installation depth: 486 - 640 mm Groundwater resistant from lower edge of base section: 3,000 mm Drain body: Socket version: including spigot and socket Vertical adjustment: vertically adjustable upper section Coverage features: Type of cover: tileable cover plate Cover material: Polymer Max. flooring height: 16 mm Load class: K 3 (EN 1253-1) Length: 366 mm Width: 366 mm Tightness: surface water resistant Locking: Lock & Lift Vertical drop between inlet and outlet: 9 mm Cable length: 5 m Motor type: KSM 140 Protection class motor: IP 68 (3m/48h) Protection class probe: IP 68 (3m/48h) Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: optical Level measurement instrument: optical probe Alarm sensor: optical probe
Installation Video
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Remote signal generator 20 m cable, 2x0.75 q | 20162 | Show | |
Clearance code for potential-free contact | 80077 | Show | |
Pumpfix F conversion kit DN 100-200, fr. 01/2011, Floor slab | 80098 | Show | |
10 m probe cable extension set | 80889 | Show | |
Cable extension set for motor 10 m | 80890 | Show | |
Cable prolongation set for pump 10 m | 80891 | Show | |
Extension section H: 200 mm | 83070 | Show | |
Extension section H: 234 mm, with flange and counter-flange | 83073 | Show | |
Extension section H: 360 mm, with central flange | 83075 | Show |
Title | Item no. | ||
---|---|---|---|
Battery 9 V block | 680034 | Show | |
Flap holder for motor-driven and mechanical flap | 680101 | Show | |
Seal for upper section, from 07/2014 | 680150 | Show | |
Seal for cover plate, System 330 mm | 686114 | Show | |
Staufix test funnel with seal | 70214 | Show | |
Dichtungsset I für Kessel-Staufix Premiu | 70318 | Show | |
Staufix Premium FKA cover | 80016 | Show | |
Staufix Premium FKA cover | 80017 | Show | |
Motor-driven backwater flap Premium | 80038 | Show | |
Insert part f. motor-driven flap Premium | 80039 | Show | |
Backwater flap / Insert Premium | 80041 | Show | |
FKA Control unit Komfort - IP54 | 80071 | Show | |
Staufix FKA drive motor (KSM 140) 5m | 80076 | Show | |
Replacement set optical probe | 80888 | Show | |
Adapter set optical probe | 80892 | Show | |
Cover, watertight, tile-over | 830052 | Show | |
Upper section System 400 | 830065 | Show | |
Staufix Premium Spigot DN 100 | 83081 | Show | |
Staufix Premium Socket DN 100 | 83085 | Show |
Catalog Page | |
---|---|
Manuals | |
CAD Data | |
Declaration of Performance |
- Groundwater resistant from lower edge of base section (ATTR-B12): 3,000 MMT
- Installation situation (ATTR-1): floor slab installation
- Country of origin (ATTR-322): DE
- Nominal size (DN) (ATTR-118): 100
- Outer diameter (OD) (ATTR-147): 110
- Net weight (ATTR-A3A): 17 KGM
- Gross weight (ATTR-A3B): 22.5 KGM
- Installation depth (ATTR-B2_VB): 486 MMT
- Vertical adjustment (ATTR-177): vertically adjustable upper section
- Delivery state (ATTR-189): Pre-mounted for final assembly on site (sensor system must be fitted on site and control unit must be connected)
- Electrical connection available (ATTR-256): yes
- Type of operating voltage (ATTR-288): alternating voltage (AC)
- Upper tolerance of the operating voltage (+) (ATTR-273): 10 PROZ
- Lower tolerance of the operating voltage (-) (ATTR-274): 10 PROZ
- Connection to the BCS, BAC (ATTR-257): yes
- Length (ATTR-A6A): 642 MMT
- Width (ATTR-A6B): 590 MMT
- Cutout dimension, length (ATTR-160): 750 MMT
- Cutout dimension, width (ATTR-161): 750 MMT
- Volume (ATTR-320): 0.3 MTQ
- Packaging dimension: length (ATTR-325): 785 MMT
- Packaging dimension: width (ATTR-326): 615 MMT
- Packaging dimension: height (ATTR-327): 550 MMT
- Dimensions (ATTR-323): 785X615X550MM
- Number of packages (ATTR-321): 1
- Type of waterproofing layer (ATTR-170): Waterproofing layer
- Emergency closure (ATTR-153): yes
- Socket version (ATTR-233): including spigot and socket
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): optical probe
- Type of level measurement (ATTR-7A): optical
- Level measurement instrument (ATTR-7B): optical probe
- Type of cover (ATTR-A21): tileable cover plate
- Load class (ATTR-A2B): K 3 (EN 1253-1)
- Tightness (ATTR-A2C): surface water resistant
- Locking (ATTR-A2D): Lock & Lift
- Cover material (ATTR-A2E): Polymer
- Max. flooring height (ATTR-A2L): 16 MMT
- Length (ATTR-A2M): 366 MMT
- Width (ATTR-A2N): 366 MMT
- Protection class motor (ATTR-174): IP 68 (3m/48h)
- Motor type (ATTR-120B): KSM 140
- Standard (ATTR-9): EN 13564
- CE marking (ATTR-A5B): yes
- Backwater protection (ATTR-151): Type 3
- Number of mechanical backwater flaps (ATTR-154): 1
- Number of motor-driven backwater flaps (ATTR-3A): 1
- External monitoring (ATTR-A8): LGA
- Cable length (ATTR-190): 5 MTR
- Declaration of Performance (DOP) (ATTR-292): 009-006
- Protection strategy (ATTR-311): Central protection
- Type of wastewater (ATTR-6): wastewater with sewage
- Position relative to sewer (ATTR-309): Gradient to the sewer
- Function in the event of backwater (ATTR-312): Protects in the event of backwater
- Protection class probe (ATTR-175): IP 68 (3m/48h)
- Colour (ATTR-102): black
- Vertical drop between inlet and outlet (ATTR-176): 9 MMT
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Backwater valves
- Product type (M-ATTR-003): Automatic backwater valve
- Product family (M-ATTR-004): Staufix
- Product name (M-ATTR-005): Staufix FKA