Skip to main content

Backwater lifting station Ecolift XL

Duo, 1 motor-driven flap, SPF 3000-S3

The backwater lifting station for non-faecal wastewater is equipped with two submersible pumps, one motor-driven and one mechanical closure system and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an enclosed pump tank. Quick-release closures enable the integrated components to be removed easily. Normally, draining takes place via the natural fall to the sewer. Backwater is detected by an optical probe, which causes the motor-driven closure system to close automatically and there is no longer free passage to the sewer. During the backwater phase, the water drains via a pressure pipe, which carries the wastewater into the sewer. The pressure pipe is a welded PE pipe; with pump SPF 4500, the pressure pipe must also be continued up to a pressure release chamber. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. The KESSEL modular system provides different upper sections and engineering chamber options as accessories.

  • Wastewater drainage without interruption, even if a power failure occurs
  • Low pump use
  • minimised noise emissions
  • ensures low power consumption
  • Reduced maintenance costs due to longer maintenance intervals in commercial/industrial use
Item no. 8741024
GTIN 4026092068410
Price group 60

Backwater lifting station Ecolift XL Duo, 1 motor-driven flap, SPF 3000-S3
The backwater lifting station for non-faecal wastewater is equipped with two submersible pumps, one motor-driven and one mechanical closure system and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an enclosed pump tank. Quick-release closures enable the integrated components to be removed easily. Normally, draining takes place via the natural fall to the sewer. Backwater is detected by an optical probe, which causes the motor-driven closure system to close automatically and there is no longer free passage to the sewer. During the backwater phase, the water drains via a pressure pipe, which carries the wastewater into the sewer. The pressure pipe is a welded PE pipe; with pump SPF 4500, the pressure pipe must also be continued up to a pressure release chamber. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. The KESSEL modular system provides different upper sections and engineering chamber options as accessories. Type of wastewater: wastewater without sewage Installation situation: free-standing set-up, underground installation, floor slab installation Version: Type of system: Twin pump station Shut-off valve: Shut-off valve made of polymer Pump control: Control unit Backflow preventer: integrated Note on installation depth: Version for deeper installation, in combination with a chamber module Passage seal for ventilation pipe (DN): 70 mm Passage seal for conduit pipe (DN): 100 mm Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) Backwater protection: Type 3 Number of mechanical backwater flaps: 1 Number of motor-driven backwater flaps: 1 General characteristics: Colour: black Approval: Z-53.2-493 Dimensions: Length: 1,245 mm Width: 1,200 mm Height: 657 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 150 Number of outlets: 1 ST Outlet nominal size (DN): 150 Distance pipe bottom inlet to tank bottom: 135 mm Distance pipe bottom outlet to tank bottom: 120 mm Tank volume: 65 l Pumping volume: 20 l Pressure pipe connection: horizontal Pressure pipe connection (DN): 80 mm Pressure pipe connection (OD): 90 mm Venting connection (DN): 70 mm Channel: continuous channel Groundwater resistant from lower edge of base section: 3,000 mm Clear width of tank (LW): 1,000 mm Nominal pressure (PN): 10 Free passage: 40 mm Pumping device: Pump: SPF 3000 Number of pumps: 2 Max. pumping capacity: 36 m3/h Max. pumping height: 17.5 m Operating mode: S3 - 50 % Power P1: 3.2 kW Power P2: 2.7 kW Speed: 2,845 U/min Type of fuse required (electrical protection): 3 x C 20 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Direct connection Weight: 24 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 5.4 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 7G 1.5 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.89 Insulation class: F Vertical drop between inlet and outlet: 15 mm Control: Control unit: Comfort Plus Operating voltage: 400 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: yes Motor protection switch: yes Standby power: 5 W Protection class control unit: IP 54 Length of mains cable for control unit: 0 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe Alarm sensor: optical probe

Installation Video

  Title Item no.  
Chamber module LW 1000 ground Access LW 800, 411-660 mm, Class K 3 8740002 Show
Chamber module LW 1000 floor slab Access LW 800, 668-917 mm, Class K 3 8740003 Show
Chamber module LW 1000 ground Access LW 800, 396-645 mm, Class A 15 8740004 Show
Chamber module LW 1000 floor slab Access LW 800, 653-902 mm, Class L 15 8740005 Show
Chamber module LW 1000 ground Access LW 800, 661-910 mm, Class K 3 8740008 Show
Chamber module LW 1000 floor slab Access LW 800, 918-1167 mm, Class K 3 8740009 Show
Chamber module LW 1000 ground Access LW 800, 646-895 mm, Class A 15 8740010 Show
Chamber module LW 1000 floor slab Access LW 800, 903-1152 mm, Class L 15 8740011 Show
Chamber module LW 1000 ground Access LW 800, 911-1160 mm, Class K 3 8740014 Show
Chamber module LW 1000 floor slab Access LW 800, 1168-1417 mm, Class K 3 8740015 Show
Chamber module LW 1000 ground Access LW 800, 896-1145 mm, Class A 15 8740016 Show
Chamber module LW 1000 floor slab Access LW 800, 1153-1402 mm, Class L 15 8740017 Show
Chamber module LW 1000 ground Access LW 600, 1130-1379 mm, Class A/B 8740018 Show
Chamber module LW 1000 ground Access LW 600, 1130-1379 mm, Class D 8740019 Show
Chamber module LW 1000 ground Access LW 800, 1161-1410 mm, Class K 3 8740020 Show
Chamber module LW 1000 floor slab Access LW 800, 1418-1667 mm, Class K 3 8740021 Show
Chamber module LW 1000 ground Access LW 800, 1146-1395 mm, Class A 15 8740022 Show
Chamber module LW 1000 floor slab Access LW 800, 1403-1652 mm, Class L 15 8740023 Show
Chamber module LW 1000 ground Access LW 600, 1380-1629 mm, Class A/B 8740024 Show
Chamber module LW 1000 ground Access LW 600, 1380-1629 mm, Class D 8740025 Show
Chamber module LW 1000 ground Access LW 800, 1411-1660 mm, Class K 3 8740026 Show
Chamber module LW 1000 floor slab Access LW 800, 1668-1917 mm, Class K 3 8740027 Show
Chamber module LW 1000 ground Access LW 800, 1396-1645 mm, Class A 15 8740028 Show
Chamber module LW 1000 floor slab Access LW 800, 1653-1902 mm, Class L 15 8740029 Show
Chamber module LW 1000 ground Access LW 600, 1630-1879 mm, Class A/B 8740030 Show
Chamber module LW 1000 ground Access LW 600, 1630-1879 mm, Class D 8740031 Show
Chamber module LW 1000 ground Access LW 800, 1661-1910 mm, Class K 3 8740032 Show
Chamber module LW 1000 ground Access LW 800, 1646-1895 mm, Class A 15 8740034 Show
Chamber module LW 1000 ground Access LW 600, 1880-2129 mm, Class A/B 8740036 Show
Chamber module LW 1000 ground Access LW 600, 1880-2129 mm, Class D 8740037 Show
Chamber module LW 1000 ground Access LW 800, 1911-2160 mm, Class K 3 8740038 Show
Chamber module LW 1000 ground Access LW 800, 1896-2145 mm, Class A 15 8740040 Show
Chamber module LW 1000 ground Access LW 600, 2130-2379 mm, Class A/B 8740042 Show
Chamber module LW 1000 ground Access LW 600, 2130-2379 mm, Class D 8740043 Show
Chamber module LW 1000 ground Access LW 800, 2161-2410 mm, Class K 3 8740044 Show
Chamber module LW 1000 ground Access LW 800, 2146-2395 mm, Class A 15 8740046 Show
Chamber module LW 1000 ground Access LW 600, 2380-2629 mm, Class A/B 8740048 Show
Chamber module LW 1000 ground Access LW 600, 2380-2629 mm, Class D 8740049 Show
Chamber module LW 1000 ground Access LW 800, 2411-2660 mm, Class K 3 8740050 Show
Chamber module LW 1000 ground Access LW 800, 2396-2645 mm, Class A 15 8740052 Show
Chamber module LW 1000 ground Access LW 600, 2630-2879 mm, Class A/B 8740054 Show
Chamber module LW 1000 ground Access LW 600, 2630-2879 mm, Class D 8740055 Show
Chamber module LW 1000 ground Access LW 800, 2661-2910 mm, Class K 3 8740056 Show
Chamber module LW 1000 ground Access LW 800, 2646-2895 mm, Class A 15 8740058 Show
Chamber module LW 1000 ground Access LW 600, 2880-3129 mm, Class A/B 8740060 Show
Chamber module LW 1000 ground Access LW 600, 2880-3129 mm, Class D 8740061 Show
Chamber module LW 1000 ground Access LW 800, 2911-3160 mm, Class K 3 8740062 Show
Chamber module LW 1000 ground Access LW 800, 2896-3145 mm, Class A 15 8740064 Show
Chamber module LW 1000 ground Access LW 800, 375-624 mm, Class K 3 8740122 Show
Chamber module LW 1000 ground Access LW 800, 625-874 mm, Class K 3 8740123 Show
Chamber module LW 1000 ground Access LW 800, 875-1124 mm, Class K 3 8740124 Show
Chamber module LW 1000 ground Access LW 800, 1125-1374 mm, Class K 3 8740125 Show
Chamber module LW 1000 ground Access LW 800, 1375-1624 mm, Class K 3 8740126 Show
Chamber module LW 1000 ground Access LW 800, 1625-1874 mm, Class K 3 8740127 Show
Chamber module LW 1000 ground Access LW 800, 1875-2124 mm, Class K 3 8740128 Show
Chamber module LW 1000 ground Access LW 800, 2125-2374 mm, Class K 3 8740129 Show
Chamber module LW 1000 ground Access LW 800, 2375-2624 mm, Class K 3 8740130 Show
Chamber module LW 1000 ground Access LW 800, 2625-2874 mm, Class K 3 8740131 Show
Chamber module LW 1000 ground Access LW 800, 2875-3124 mm, Class K 3 8740132 Show
Chamber module LW 1000 ground Access LW 800, 620-869 mm, Class B 8740141 Show
Chamber module LW 1000 ground Access LW 800, 870-1119 mm, Class B 8740142 Show
Chamber module LW 1000 ground Access LW 800, 1120-1369 mm, Class B 8740143 Show
Chamber module LW 1000 ground Access LW 800, 620-869 mm, Class D 8740158 Show
Chamber module LW 1000 ground Access LW 800, 870-1119 mm, Class D 8740159 Show
Chamber module LW 1000 ground Access LW 800, 1120-1369 mm, Class D 8740160 Show
  Title Item no.  
  Title Item no.  
Remote signal generator 20 m cable, 2x0.75 q 20162 Show
Compressor set for air bubbling 28048 Show
TeleControl GSM modem for Comfort control units 230V/400V 28792 Show
Intermediate section 250 mm, for chamber module LW 1000 680370 Show
Intermediate section 500 mm, for chamber module LW 1000 680371 Show
10 m probe cable extension set 80889 Show
Cable extension set for motor 10 m 80890 Show
Cable prolongation set for pump 10 m 80891 Show
Installation set Thermostat, Hygrostat 97713 Show
Outdoor control cabinet W: 590 mm, for control unit installation 97714 Show
Warning beacon for outdoor control cabinet 97715 Show
Outdoor control cabinet W: 460 mm, for control unit installation 97716 Show
Outdoor control cabinet W: 785 mm, for control unit installation 97723 Show
Outdoor control cabinet W: 1115 mm, for control unit installation 97724 Show
  Title Item no.  
Splash guard set for optical probe 28706 Show
Comfort PLUS 400V 4,0-6,3A 28787 Show
Battery 9 V block 680034 Show
Seal for SPF 1400 - SPF 4500 680052 Show
Pressure hose Sold by the metre, 6x4 mm 100 680071 Show
Flap holder for motor-driven and mechanical flap 680101 Show
One-handed closure DN 63 680380 Show
Backflow preventer left, with non-return flap 680381 Show
Backflow preventer right, with non-return flap 680382 Show
Pressure pipe with shut-off valve Left-hand version 680383 Show
Pressure pipe with shut-off valve Right-hand version 680384 Show
Pressure hose Ecolift XL 680385 Show
Valve key for shut-off valve DN 63 680386 Show
Ecolift XL lockable cover Outlet side 680391 Show
Support rib for shut-off valve, straight support 680397 Show
Pump flange Ecolift XL, incl. seal 680398 Show
Pump plate Ecolift XL 680399 Show
Seal set Ecolift XL 680418 Show
Drive motor for clamping on, 10 m cable 680452 Show
Spare part set, optical probe 10 m cable 680455 Show
Pump drive SPF 3000 400 V, S3, 10 m cable 680524 Show
Immersion pipe for Ecolift XL, 180 mm 680827 Show
Motor-driven backwater flap Premium 80038 Show
Insert part f. motor-driven flap Premium 80039 Show
Backwater flap / Insert Premium 80041 Show
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Number of motor-driven backwater flaps (ATTR-3A): 1
  • TÜV test mark (ATTR-376): ID 1111241794
  • Country of origin (ATTR-322): DE
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): Freestanding pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for three-phase current
  • E-motor, type of startup (ATTR-271): direct
  • Pump casing material (ATTR-272): Grey iron
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 3/N/PE 400V
  • Startup circuit for three-phase connection or three-phase current (ATTR-278): Star
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): MS
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 1,600  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 41  AMP
  • Vertical installation (ATTR-286): yes
  • Operating mode, twin systems (ATTR-287): redundant
  • Pump (ATTR-4): SPF 3000
  • Number of pumps (ATTR-181): 2
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 7G 1.5 mm2
  • Type of fuse required (electrical protection) (ATTR-N3): 3 x C 20 A
  • Max. permissible switching frequency (ATTR-162): 20  1PH
  • Operating mode (ATTR-10): S3 - 50 %
  • Power P1 (ATTR-F4): 3.2  KWT
  • Power P2 (ATTR-F5): 2.7  KWT
  • Speed (ATTR-F2): 2,845  UMIN
  • Rated current (ATTR-N5): 5.4  AMP
  • Max. pumping capacity (ATTR-F7): 36  MQH
  • Max. pumping height (ATTR-F8): 17.5  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): Direct connection
  • Protection class (pump) (ATTR-125): IP 68 (3m/48h)
  • Length of mains cable for pump (ATTR-11): 10  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Weight (ATTR-191): 24  KGM
  • Cos phi - power factor (ATTR-192): 0.9
  • Insulation class (ATTR-193): F
  • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
  • Expected service life (number of switching cycles) (ATTR-195): 150,000
  • Net weight (ATTR-A3A): 152  KGM
  • Gross weight (ATTR-A3B): 176  KGM
  • Installation situation (ATTR-1): free-standing set-up
  • Shut-off valve (ATTR-A1): Shut-off valve made of polymer
  • Pressure pipe connection (ATTR-B7): horizontal
  • Type of system (ATTR-2): Twin pump station
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Control unit
  • Note on installation depth (ATTR-188): Version for deeper installation
  • Passage seal for ventilation pipe (DN) (ATTR-183): 70  MMT
  • Passage seal for conduit pipe (DN) (ATTR-184): 100  MMT
  • Length (ATTR-A6A): 1,245  MMT
  • Width (ATTR-A6B): 1,200  MMT
  • Height (ATTR-A6C): 657  MMT
  • Volume (ATTR-320): 2.5  MTQ
  • Packaging dimension: length (ATTR-325): 2,000  MMT
  • Packaging dimension: width (ATTR-326): 1,300  MMT
  • Packaging dimension: height (ATTR-327): 950  MMT
  • Dimensions (ATTR-323): 1300X1300X900/700X800X950MM
  • Number of packages (ATTR-321): 2
  • Control unit (ATTR-S2): Comfort Plus
  • Self-diagnosis system (SDS) (ATTR-S5): yes
  • Battery buffering (ATTR-S6): yes
  • Multi-line display (ATTR-S7): yes
  • Log book function (ATTR-S8): yes
  • USB interface (ATTR-S9): yes
  • GSM interface (ATTR-S10): yes
  • Potential-free contact (ATTR-S11): yes
  • Length of mains cable for control unit (ATTR-S12): 0  MTR
  • Operating voltage (ATTR-S13): 400  VLT
  • Mains frequency (ATTR-S14): 50  HTZ
  • Protection class control unit (ATTR-S4): IP 54
  • Alarm sensor (ATTR-S1): optical probe
  • Type of level measurement (ATTR-7A): pneumatic
  • Level measurement instrument (ATTR-7B): Immersion pipe
  • Motor protection switch (ATTR-172): yes
  • Clear width of tank (LW) (ATTR-B14): 1,000  MMT
  • Number of inlets (ATTR-B1B): 1  PCE
  • Inlet nominal size (DN) (ATTR-B1CA): 150  MMT
  • Distance pipe bottom inlet to tank bottom (ATTR-B1D): 135  MMT
  • Number of outlets (ATTR-B15B): 1  PCE
  • Outlet nominal size (DN) (ATTR-B15CA): 150
  • Distance pipe bottom outlet to tank bottom (ATTR-B15D): 120  MMT
  • Channel (ATTR-158): continuous channel
  • Venting connection (DN) (ATTR-B4): 70  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 80  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 90  MMT
  • Nominal pressure (PN) (ATTR-B18B): 10
  • Tank volume (ATTR-B9): 65  LTR
  • Pumping volume (ATTR-B10): 20  LTR
  • Groundwater resistant from lower edge of base section (ATTR-B12): 3,000  MMT
  • Declaration of Performance (DOP) (ATTR-292): 009-033
  • Wastewater quantity (ATTR-310): High
  • Protection strategy (ATTR-311): Central protection
  • Position relative to sewer (ATTR-309): Gradient to the sewer
  • Function in the event of backwater (ATTR-312): Drains in the event of backwater
  • Colour (ATTR-102): black
  • Note on type of wastewater (ATTR-187): Country-specific regulations related to the area of application can deviate
  • Approval (ATTR-A5): Z-53.2-493
  • Backwater protection (ATTR-151): Type 3
  • Number of mechanical backwater flaps (ATTR-154): 1
  • Vertical drop between inlet and outlet (ATTR-176): 15  MMT
  • Free passage (ATTR-180): 40  MMT
  • Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
  • Standard (ATTR-9):
  • Declaration of conformity (ATTR-289): yes
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Hybrid lifting stations
  • Product type (M-ATTR-003): Backwater lifting station
  • Product family (M-ATTR-004): Ecolift
  • Product name (M-ATTR-005): Ecolift XL
  • Standby power (ATTR-S20): 5  WTT