    Type of wastewater: wastewater with sewage Installation situation: installation in on-site collecting tank Version: Type of system: Twin pump station Installation: Wet installation Pump control: Control unit Backflow preventer: integrated Delivery state: Modular set for assembly on site General characteristics: Standard: EN 12050-2 Tank: Pressure pipe connection: horizontal Pressure pipe connection (DN): 50 mm Pressure pipe connection (OD): 63 mm Pumping device: Pump: STZ 2500 Number of pumps: 2 Max. pumping capacity: 21 m3/h Max. pumping height: 33 m Operating voltage: 400 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 2.5 kW Power P2: 1.9 kW Speed: 2,900 U/min Type of fuse required (electrical protection): 3 x C 20 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Impeller type: Macerator Length of mains cable for pump: 10 m Rated current: 4.4 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN8-F 6G 1.5 mm2 Temperature monitoring: integrated Control: Control unit: Comfort Operating voltage: 400 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Type of fuse required (electrical protection): 3 x C 20 A Protection class control unit: IP 54 Type of level measurement: hydrostatic Level measurement instrument: Level sensor Alarm sensor: Level sensor
      Title Item no.  
      Title Item no.  
      Title Item no.  
      Title Item no.  
    • Pump (ATTR-4): STZ 2500
    • Number of pumps (ATTR-181): 2
    • Impeller type (ATTR-8): Macerator
    • Type of fuse required (electrical protection) (ATTR-N3): 3 x C 20 A
    • Operating mode (ATTR-10): S1
    • Power P1 (ATTR-F4): 2.5  KWT
    • Power P2 (ATTR-F5): 1.9  KWT
    • Operating voltage (ATTR-131): 400  VLT
    • Mains frequency (ATTR-N4): 50  HTZ
    • Rated current (ATTR-N5): 4.4  AMP
    • Max. pumping capacity (ATTR-F7): 21  MQH
    • Max. pumping height (ATTR-F8): 33  MTR
    • Protection class (pump) (ATTR-125): IP 68 (3m)
    • Length of mains cable for pump (ATTR-11): 10  MTR
    • Number of packages (ATTR-321): 0
    • Shut-off valve (ATTR-A1): yes
    • Type of system (ATTR-2): Twin pump station
    • Backflow preventer (ATTR-165): integrated
    • Pressure pipe connection (DN) (ATTR-B17): 50  MMT
    • Pressure pipe connection (OD) (ATTR-B18): 63  MMT
    • Control unit (ATTR-S2): Comfort
    • Self-diagnosis system (SDS) (ATTR-S5): yes
    • Multi-line display (ATTR-S7): yes
    • GSM interface (ATTR-S10): yes
    • Potential-free contact (ATTR-S11): optional
    • Level measurement instrument (ATTR-7B): Level sensor
    • ATEX (ATTR-136): ja
    • Type of wastewater (ATTR-6): wastewater with sewage
    • Type of pump connection cable (ATTR-N2): H07RN8-F 6G 1.5 mm2
    • Speed (ATTR-F2): 2,900  UMIN
    • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): coded plug
    • Temperature monitoring (ATTR-135): integrated
    • Pressure pipe connection (ATTR-B7): horizontal
    • Pump control (ATTR-134): Control unit
    • Battery buffering (ATTR-S6): yes
    • Log book function (ATTR-S8): yes
    • USB interface (ATTR-S9): yes
    • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
    • Operating voltage (ATTR-S13): 400  VLT
    • Mains frequency (ATTR-S14): 50  HTZ
    • Protection class control unit (ATTR-S4): IP 54
    • Alarm sensor (ATTR-S1): Level sensor
    • Type of level measurement (ATTR-7A): hydrostatic
    • Type of fuse required (electrical protection) (ATTR-S17): 3 x C 20 A
    • Standard (ATTR-9): EN 12050-2
    • Installation situation (ATTR-1): installation in on-site collecting tank
    • Delivery state (ATTR-189): Modular set for assembly on site
    • Installation (ATTR-164): Wet installation