Backwater pumping station, Pumpfix F
DN 150, exposed
The premium backwater pumping station for faecal and non-faecal wastewater is equipped with a pump and a motor-driven closure system. The pipe cross-section is normally open. In case of backwater, the motor-driven closure system is closed automatically. During the backwater phase, the water drains via the pump with integrated macerator. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface.
- Backwater pumping station: uses the natural fall to the sewer - pump is only used for backwater
- Flexible installation, different covers with drain function available for installation in the floor slab
- Quiet and energy-saving
Item no. | 24150 |
---|---|
GTIN | 4026092046500 |
Price group | 30 |
Backwater pumping station, Pumpfix F DN 150, exposed
The premium backwater pumping station for faecal and non-faecal wastewater is equipped with a pump and a motor-driven closure system. The pipe cross-section is normally open. In case of backwater, the motor-driven closure system is closed automatically. During the backwater phase, the water drains via the pump with integrated macerator. The station is controlled by a user-friendly control unit, which is optionally integrated in the building management system via a potential-free contact, or alarm and collective fault messages can be output via a GSM interface. Type of wastewater: wastewater with sewage Installation situation: exposed drainage pipe Version: Emergency closure: yes Pump control: Control unit Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) Number of motor-driven backwater flaps: 1 General characteristics: Nominal size (DN): 150 Outer diameter (OD): 160 Colour: black Approval: Z-53.2-388 Dimensions: Length: 656 mm Width: 350 mm Height: 422 mm Drain body: Socket version: including spigot and socket Coverage features: Type of cover: Protective cover Cover material: Polymer Colour of cover: transparent Length: 542 mm Width: 350 mm Height: 165 mm Locking: Clip closure Pumping device: Pump: SPZ 1000 Number of pumps: 1 Max. pumping capacity: 11.5 m3/h Max. pumping height: 10 m Operating mode: S3 - 50 % Power P1: 1.2 kW Power P2: 0.69 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Macerator Length of mains cable for pump: 5 m Rated current: 5.2 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.97 Insulation class: F Vertical drop between inlet and outlet: 9 mm Motor type: KSM 140 Protection class motor: IP 68 (3m/48h) Protection class probe: IP 68 (3m/48h) Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: optical Level measurement instrument: optical probe Alarm sensor: optical probe
Installation Video
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
Pump cover inlet side | 28052 | Show | |
Pumpfix F Premium Komf. Cover outlet s. | 28056 | Show | |
Vent for Pumpfix Premium | 28060 | Show | |
Active carbon filter | 28061 | Show | |
Pumpfix F Control Unit Komfort - IP 54 | 28071 | Show | |
Replacement pump AqualiftF/Pumpfix F | 28351 | Show | |
One-handed closure for backflow preventer | 680018 | Show | |
Battery 9 V block | 680034 | Show | |
Flap holder for motor-driven and mechanical flap | 680101 | Show | |
Pressure pipe connection with backflow preventer | 680104 | Show | |
Gasket set (Pumpfix, Ecolift) | 70319 | Show | |
Motor-driven backwater flap Premium | 80038 | Show | |
Insert part f. motor-driven flap Premium | 80039 | Show | |
Staufix FKA drive motor (KSM 140) 5m | 80076 | Show | |
Replacement set optical probe | 80888 | Show | |
Adapter set optical probe | 80892 | Show | |
FKA Staufix Protective cover | 83031 | Show | |
FKA Staufix transition piece | 83032 | Show | |
Staufix Premium Spigot DN 150 | 83083 | Show | |
Staufix Premium Socket DN 150 | 83087 | Show |
Catalog Page | |
---|---|
Manuals | |
CAD Data | |
Approval | |
Test Reports and Certificates | |
Declaration of Performance | |
Declaration of Conformity |
- Installation situation (ATTR-1): exposed drainage pipe
- Country of origin (ATTR-322): DE
- Area of application (ATTR-264): drainage
- Pump type (ATTR-265): Freestanding pump
- Pump shaft position (ATTR-266): vertical
- Pump design (ATTR-267): Dry rotor pump
- Pump hydraulics (ATTR-268): single stage
- Pump suction characteristic (ATTR-269): non-self-priming
- Pump drive (ATTR-270): E-motor for alternating current
- E-motor, type of startup (ATTR-271): direct
- Pump casing material (ATTR-272): Polymer
- Upper tolerance of the nominal frequency (+) (ATTR-275): 3 PROZ
- Lower tolerance of the nominal frequency (-) (ATTR-276): 2 PROZ
- Pump electrical connection (ATTR-277): 1/N/PE 230V
- Motor pump shaft (ATTR-279): continuous
- Shaft seal (ATTR-280): RSSR
- Minimum pumped media temperature (ATTR-282): 0 CEL
- Maximum operating pressure (Pmax) (ATTR-283): 1,000 HPA
- Minimum speed for speed adjustment (ATTR-284): no speed adjustment
- Start-up current (ATTR-285): 14.9 AMP
- Vertical installation (ATTR-286): yes
- Pump (ATTR-4): SPZ 1000
- Number of pumps (ATTR-181): 1
- Impeller type (ATTR-8): Macerator
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Max. permissible switching frequency (ATTR-162): 20 1PH
- Operating mode (ATTR-10): S3 - 50 %
- Power P1 (ATTR-F4): 1.2 KWT
- Power P2 (ATTR-F5): 0.7 KWT
- Speed (ATTR-F2): 2,800 UMIN
- Rated current (ATTR-N5): 5.2 AMP
- Max. pumping capacity (ATTR-F7): 11.5 MQH
- Max. pumping height (ATTR-F8): 10 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): coded plug
- Protection class (pump) (ATTR-125): IP 68 (3m/48h)
- Length of mains cable for pump (ATTR-11): 5 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 10 KGM
- Cos phi - power factor (ATTR-192): 1.0
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 5,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 150,000
- Nominal size (DN) (ATTR-118): 150
- Outer diameter (OD) (ATTR-147): 160
- Net weight (ATTR-A3A): 22.3 KGM
- Gross weight (ATTR-A3B): 22.4 KGM
- Emergency closure (ATTR-153): yes
- Pump control (ATTR-134): Control unit
- Socket version (ATTR-233): including spigot and socket
- Length (ATTR-A6A): 656 MMT
- Width (ATTR-A6B): 350 MMT
- Height (ATTR-A6C): 422 MMT
- Volume (ATTR-320): 0.1 MTQ
- Packaging dimension: length (ATTR-325): 785 MMT
- Packaging dimension: width (ATTR-326): 385 MMT
- Packaging dimension: height (ATTR-327): 465 MMT
- Dimensions (ATTR-323): 790X400X490MM
- Number of packages (ATTR-321): 1
- Control unit (ATTR-S2): Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): optical probe
- Type of level measurement (ATTR-7A): optical
- Level measurement instrument (ATTR-7B): optical probe
- Type of cover (ATTR-A21): Protective cover
- Colour of cover (ATTR-A2A): transparent
- Locking (ATTR-A2D): Clip closure
- Cover material (ATTR-A2E): Polymer
- Length (ATTR-A2M): 542 MMT
- Width (ATTR-A2N): 350 MMT
- Height (ATTR-A2P): 165 MMT
- Declaration of Performance (DOP) (ATTR-292): 009-040
- Declaration of conformity (ATTR-303): 009-567
- Protection strategy (ATTR-311): Individual protection
- Type of wastewater (ATTR-6): wastewater with sewage
- Position relative to sewer (ATTR-309): Gradient to the sewer
- Function in the event of backwater (ATTR-312): Drains in the event of backwater
- Protection class probe (ATTR-175): IP 68 (3m/48h)
- Colour (ATTR-102): black
- Protection class motor (ATTR-174): IP 68 (3m/48h)
- Motor type (ATTR-120B): KSM 140
- Approval (ATTR-A5): Z-53.2-388
- Number of motor-driven backwater flaps (ATTR-3A): 1
- External monitoring (ATTR-A8): LGA
- Vertical drop between inlet and outlet (ATTR-176): 9 MMT
- Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Hybrid lifting stations
- Product type (M-ATTR-003): Backwater pumping station
- Product family (M-ATTR-004): Pumpfix
- Product name (M-ATTR-005): Pumpfix F